#include <em_vcmp.h>
Data Fields | |
int | biasProg |
bool | enable |
bool | halfBias |
VCMP_Hysteresis_TypeDef | hyst |
int | inactive |
bool | irqFalling |
bool | irqRising |
bool | lowPowerRef |
int | triggerLevel |
VCMP_WarmTime_TypeDef | warmup |
int VCMP_Init_TypeDef::biasProg |
BIAS current configuration, depends on halfBias setting, above, see reference manual
Definition at line 102 of file em_vcmp.h.
Referenced by VCMP_Init().
bool VCMP_Init_TypeDef::enable |
Enable VCMP after configuration
Definition at line 119 of file em_vcmp.h.
Referenced by VCMP_Init(), and VDDCHECK_LowVoltage().
bool VCMP_Init_TypeDef::halfBias |
If set to true, will reduce by half the bias current
Definition at line 99 of file em_vcmp.h.
Referenced by VCMP_Init().
VCMP_Hysteresis_TypeDef VCMP_Init_TypeDef::hyst |
int VCMP_Init_TypeDef::inactive |
Output value when comparator is inactive, should be 0 or 1
Definition at line 112 of file em_vcmp.h.
Referenced by VCMP_Init().
bool VCMP_Init_TypeDef::irqFalling |
Enable interrupt for falling edge
Definition at line 104 of file em_vcmp.h.
Referenced by VCMP_Init().
bool VCMP_Init_TypeDef::irqRising |
Enable interrupt for rising edge
Definition at line 106 of file em_vcmp.h.
Referenced by VCMP_Init().
bool VCMP_Init_TypeDef::lowPowerRef |
Enable low power mode for VDD and bandgap reference
Definition at line 114 of file em_vcmp.h.
Referenced by VCMP_Init(), and VDDCHECK_LowVoltage().
int VCMP_Init_TypeDef::triggerLevel |
Trigger level, according to formula VDD Trigger Level = 1.667V + 0.034V x triggerLevel
Definition at line 117 of file em_vcmp.h.
Referenced by VCMP_Init(), and VDDCHECK_LowVoltage().
VCMP_WarmTime_TypeDef VCMP_Init_TypeDef::warmup |
Warm-up time in clock cycles
Definition at line 108 of file em_vcmp.h.
Referenced by VCMP_Init(), and VDDCHECK_LowVoltage().